When visual inspection reveals anomalies, the standard guides the engineer into the "Detailed Assessment" phase. It outlines various Non-Destructive Testing (NDT) methods—such as ultrasonic testing, magnetic particle testing, and radiography—and explains when to apply them. It also covers destructive testing, such as core sampling, detailing how to extract samples without compromising structural integrity.